Maintenance-Object Repair Procedures
555-233-143
8-1176 Issue 1 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. This error indicates a hardware failure with the port circuitry which provides
the packet-bus maintenance functions. Replace the Maintenance/Test
circuit pack if the alarm is not resolved by the test command above.
b. The port has been busied out via the busyout port UUCSSpp command.
c. This error indicates that the Maintenance/Test packet-bus port has
reconfigured the packet bus by swapping a bad lead to a spare. Note that
this error is sent up whenever the Maintenance/Test packet-bus port is
initialized (since the packet-bus port reconfigures the packet bus to
whatever state it determines the packet bus is in). This will occur if the
circuit pack is inserted, if the system is restarted, or if the port is released
from a busyout state. Therefore, it is normal for this error to be present in
the error log.
If the M/T-PKT reconfigures the packet bus 6 times within 15 minutes, a
Minor alarm is raised indicating that either:
■ Packet-bus maintenance functions are not operating correctly
■ Many changes are taking place on the packet bus (insertions or
removals of circuit packs)
M/T-PKT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest port UUCSSpp
1 (a) 41018 none MINOR ON test port UUCSSpp l r 3
18 (b) 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
257 (c) Any none MINOR ON
513 (d) Any Packet Bus Port Health
Inquiry test (#567)
MINOR ON test port UUCSSpp r 3