M/T-PKT (Maintenance/Test Packet Bus Port)
Issue 1 May 2002
8-1179555-233-143
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the packet-bus fault-detection and maintenance function of
the M/T-PKT is functioning properly. This is done by having the M/T-PKT perform
a self-test. If the self-test passes, then the Packet Bus Port Health Inquiry test
passes. If the self-test fails or the Avaya MultiVantage™ software cannot
communicate with the M/T-PKT, then the test fails
Table 8-483. Test #567 Consistency Test
Error
Code
Tes t
Result Description / Recommendation
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT System resources necessary to run this test are not available.
2500 ABORT An internal operation failed, and the test could not be completed.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2059 FAIL The M/T-PKT has reported a failure of the on-board self-test.
2060 FAIL The M/T-PKT has reported an invalid state for the packet bus.
2061 FAIL The Avaya MultiVantage™ software cannot communicate with the M/T-PKT,
but can communicate with the Maintenance/Test circuit pack.
1. Retry the command.
2. If the test continues to fail, replace the Maintenance/Test circuit pack, and
retry the command.
3. If the test continues to fail, see‘‘PKT-BUS (Packet Bus)’’ on page 8-1230 to
determine whether the M/T-PKT failure is being caused by a packet-bus
fault.
PASS The M/T-PKT packet-bus fault-detection capability is operating correctly.
Continued on next page