OPS-LINE (DS1 Off-Premises Station Line)
Issue 1 May 2002
8-1187555-233-143
Any FAIL The test failed. This can be due to on-board or off-board problems. Off-board
problems of concern include EXP-PN and EXP-INTF faults, TDM-BUS faults,
and faults associated with the tone detectors/tone generators. Clear every
off-board problem before replacing the board. Keep in mind that a TDM-BUS
problem is usually the result of a faulty board connected to the backplane or
bent pins on the backplane.
1. Resolve any TONE-BD and/or TONE-PT errors.
2. Retest when the faults from step 1 are cleared.
PASS The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and by examining station,
trunk, or external wiring.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Table 8-485. Test #6 NPE Crosstalk Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page