PDMODULE (Processor Data Module) TDMODULE
(Trunk Data Module)
Issue 1 May 2002
8-1197555-233-143
Stand-Alone DCP Data Modules
There are two types of stand-alone DCP data modules:
Data Adapters
TN2136 circuit packs use IDCP signaling and a DAA2 Data Adaptor (DA) to
interface to DTE. DAs can operate in either of two modes which are covered by
different MOs:
Table 8-489. Stand-Alone DCP Data Modules
Type Name
1
1. Early versions of these data modules were referred to as PDMs and TDMs, respectively. Later models are
designed to provide a variety of interfaces by using interchangeable modules and are thus called modular
data modules. Both types are supported by the tests described in this section
Interfaces to:
MPDM Modular Processor
Data Module
DTE (data terminals, host computers, printers, etc.)
MTDM Modular Trunk Data
Module
DCE (modems, data modules, etc.)
Table 8-490. Data Adaptor Modes
DA Mode Administered as: Endpoint
Maintenance
Object
Stand-Alone PDM data endpoint only PDMODULE
Linked DTDM IDT1/2
1
and optional data terminal
1. IDT1/2: Italtel Digital Telephone, Model 1 or 2 (also known as Digital Telephones TD7210 and TD7206).
DIG-LINE