Maintenance-Object Repair Procedures
555-233-143
8-1200 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-491. PDMODULE, TDMODULE Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0 (a) 0 None
1 (b,n) 40987 None WARNING OFF
1 (c,n) 1 20 None WARNING OFF
15 (d) Any None
18 (e) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
257 (f) 40971 None
513 0 Data Module audits
(#17)
WARNING OFF test port UUCSSpp sh r
6
769 (g,n) 40988 None WARNING OFF
1281 Any Data Module audits
(#17)
WARNING OFF test port UUCSSpp sh r
4
1537 (h,n) 40968 None WARNING OFF
1793 Information Channel
and Control Channel
Looparound (#13)
MINOR ON test port UUCSSpp l r 3
2049 NPE Crosstalk (#9) MINOR ON test port UUCSSpp l r 3
2304 (i) None
2305 (j) 32770 None
2305 (k) 40967 None
2561 (l) Any Data Module Internal
Looparound (#175)
WARNING OFF test port UUCSSpp l r 5
2817 (m) Link GPP Loop (#183)
Against Links
MAJOR ON
3841 (n) NONE
3841 (o) None