PDMODULE (Processor Data Module) TDMODULE
(Trunk Data Module)
Issue 1 May 2002
8-1205555-233-143
With the port still in loop-around mode, the S Channel Loop-around test is
performed next. This test consists of sending four different transparent patterns to
the on-board microprocessor, receiving them back, and comparing them.
The third test is a loop around test for the secondary information channel. It is
performed only if a secondary data module is assigned to the port.
The fourth test is a Conference test of the primary channel. This is the same test
as Analog Line Conference test (#6).
Only one result is reported for the three tests run. If any test fails or aborts, the
sequence is stopped.
Table 8-493. Test #13 Information and Control Channel Local Loop Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the data module
extension. Then use status data module command with the extension
number to determine the service state of the data module. If the service
state indicates that the data module is in use, then the port is unavailable
for certain tests. You must wait until the port is idle before retesting.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
Continued on next page