Maintenance-Object Repair Procedures
555-233-143
8-1208 Issue 1 May 2002
5 ABORT Ringer update aborted (data module not in the in-service state)
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring, check for faulty
wiring, check for faulty data module.
3. Retry the command at 1-minute intervals up to 5 times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit pack and repeat
the test.
6 ABORT Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command (the
display shows that the port is a TTI port) or the list config command (the
display shows a t for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
2000 ABORT Response to the test was not received within the allowable time period.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Data Module audits passed. This digital port circuit pack is functioning properly.
1. If complaints still exist, investigate by using other port tests and by
examining the data module options, wiring, and connections.
Table 8-494. Test #17 Data Module Audits Test — Continued
Error
Code
Te s t
Result Description / Recommendation
Continued on next page