PDMODULE (Processor Data Module) TDMODULE
(Trunk Data Module)
Issue 1 May 2002
8-1211555-233-143
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a t for the port).
2. If either list config or display port indicate that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct for the test, and no action is necessary.
2005 ABORT The handshake between the Maintenance/Test digital port and the Data
Module failed.
1. Look for M/T-DIG errors in the Error Log. If present, see ‘‘M/T-DIG
(Maintenance/Test Digital Port)’’.
2. If test still aborts on retry, check physical connection of data module under
test. Make sure the switches are on NORM, OFF (between REM_LP and
LOC_LP), 9600, and ASYN.
3. If the test still aborts, replace the Data Module.
2312 ABORT The loop-around test did not complete, failed to receive loop-back data.
1. Check for M/T-DIG error in the Error Log. If present, see ‘‘M/T-DIG
(Maintenance/Test Digital Port)’’.
2. Retry the test, if still aborts, replace the Data Module.
3. If the test aborts again, replace the Digital Line circuit pack.
2313 ABORT The Maintenance/Test digital port allocated for this test did not respond to
downlinked message.
1. Look for M/T-DIG errors in the Error Log. If present, see ‘‘M/T-DIG
(Maintenance/Test Digital Port)’’.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort, replace the MTB.
2314 ABORT Data Module did not respond to downlinked message.
1. Check the wiring of the Data Module under test.
2. Verify that the Data Module is powered (power LED on).
3. Make sure the switches are on NORM, OFF (between REM_LP and LOC_
LP), 9600, and ASYN.
4. If the test still aborts, replace the Date Module.
5. If the same abort code appears, replace the Digital Line circuit pack that is
connected to the Data Module.
Table 8-495. Test #175 Data Module Internal Loop-Around Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page