PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1217555-233-143
Table 8-496. PRI Endpoint Port Service States
Service
State
1
Alarm Possible Cause Possible Solution
OOS/NE Warning Port has been busied out by
command.
Enter release pri-endpoint extension.
Minor NPE Crosstalk test (#6)
failed.
Replace UDS1 circuit pack.
UDS1 circuit pack lost its
signal.
Is the UDS1 circuit pack removed? Is the
UDS1 cable disconnected? Is the far-end
terminal restarting or experiencing
problems? Check circuit pack using
procedures UDS1-BD.
OOS/FE Warning Far-end problems or
incompatibility
Check administration and status of the
corresponding port on the terminal
adapter.
Warning The far-end port is busied
out.
Check the status of the far-end terminal
adapter.
OOS/FE
PINS
Service message was sent
and the switch is waiting up
to 2 minutes for a reply from
the far-end terminal adapter.
Wait 2 minutes, and check service state
after the PINS state has cleared.
MTC/NE System link demand busied
out
Check link status. Release with release
link link#.
MTC/FE Warning Signaling channel has been
down for over 90 sec.
Consult ISDN-SGRP, ISDN-LNK and/or
SYS-LINK. Far-end terminal adapter may
currently be restarting.
Warning Repeated failure of far end
to respond to messages.
Maintenance software will periodically try
to resend messages. You can speed the
process with test port UUCSSpp (Test
#256).
Warning The far-end port is being
tested.
Check status of the far-end terminal
adapter.
MTC/FE
PINS
Service message was sent,
and the switch is waiting up
to 2 minutes for a reply from
the far-end terminal adapter.
Wait 2 minutes, and check service state
after the PINS state has cleared.
Continued on next page

Table of Contents