PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1219555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. These error types indicate a disagreement between this switch and the
terminal adapter at the other end of the connection with regard to the ISDN
call state of the PRI endpoint port. This switch will automatically try to
recover by clearing the call (the call will be torn down). Use the status
pri-endpoint extension command to determine the state of the port.
When running the short test sequence, pay close attention to the results of
the Call State Audit test (#257).
b. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors.
c. The PRI endpoint port has been busied out by busyout pri-endpoint
extension or busyout port UUCSSpp. No wideband calls can be made to
this port, although wideband calls can still be made to other ports within
this PRI endpoint if they are in service.
Table 8-497. PRI endpoint port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) Any None test port UUCSSpp sh r 1
15 (b) Any Audit and Update test (#36)
18 (c) 0 busyout pri-endpoint
extension
busyout port UUCSSpp
release pri-endpoint
extension release port
UUCSSpp
129 (d) None WARNING OFF test port UUCSSpp sh r 1
130 (e) None WARNING ON test port UUCSSpp sh
257 (f) Any None test port UUCSSpp sh r 1
513 (g) Any None WARNING OFF test port UUCSSpp sh r 1
769 (f) Any None test port UUCSSpp sh r 1
1281 (h) Any Conference Circuit test (#7) MINOR ON test port UUCSSpp l r 4
1537 (i) Any NPE Crosstalk test (#6) MINOR ON test port UUCSSpp l r 3
1793 (j) Any None test port UUCSSpp sh r 1
3073 (k) Any Service State audit (#256) test port UUCSSpp sh r 2
3585 (l) Any None None