PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1221555-233-143
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Crosstalk test (#6), you may also clear errors generated from other tests in
the testing sequence.
PE-BCHL Error 3585 Aux Data
Aux
Data Meaning
10 A call in a stable, talking state (the active state) was cleared unexpectedly by the far-end
terminal adapter with an ISDN RESTART message.
4
7
8
260
263
A call that has not reached the active state, but has at least reached a ringing state, was
cleared unexpectedly by the far-end terminal adapter with an ISDN RESTART message.
1
3
6
265
A call that has not yet reached a ringing state was cleared unexpectedly by the far-end
terminal adapter with an ISDN RESTART message.
11
12
19
531
267
268
A call that was already in the process of clearing has been cleared by the far-end terminal
adapter with an ISDN RESTART message. If this condition occurs frequently, it may
mean that the far-end terminal adapter is attempting to clear ports that it thinks are in a
“hung” state. The RESTART message puts the port in an idle condition.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6) X ND
Conference Circuit test (#7) X ND
Audit and Update test (#36) X X ND
Signaling Link State Check test (#255) X X ND
Service State Audit test (#256) X X ND
Call State Audit test (#257) X X ND