PE-BCHL (PRI Endpoint Port)
Issue 1 May 2002
8-1223555-233-143
2020 ABORT The test did not run due to an existing error on the specific port or a more
general circuit pack error.
1. Examine the Error Log for existing errors against this port or the circuit
pack, and follow recommended procedures.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections. The PE-BCHL is moved to
out-of-service/near-end state.
1. Replace the circuit pack.
PASS The port can communicate over the TDM bus.
Table 8-498. Test #6 NPE Crosstalk Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page