Maintenance-Object Repair Procedures
555-233-143
8-1272 Issue 1 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. The PMS Link has been busied out with the busyout pms-link command.
The link is torn down. Enter the release pms-link command to restore the
link.
b. The Link Retry test (#215) fails. An error was detected when setting up the
link. Refer to the Procedures for Restoring the PMS Link above.
Table 8-515. PMS Link Maintenance Error Log Entries
Error
Type Aux Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test pms sh r 1
18 (a) 0 busyout pms-link WARNING OFF release pms-link
257 (b) Any Link Retry test (#215) MINOR
WARNING
2
2. Minor alarms on this MO may be down graded to Warning alarms based o the value in the set options
command.
OFF test pms-link l
513 (c) Any None test pms-link
769 (d) Any None
1025 (e) 40–49 None
1281 (f) 10–19 None
1537 (g) N0–N9 None
1793 (h) Any None test pms-link
2049 (i) Any None
2305 (j) 50–59 None release pms-link, or
test pms-link
2561 (k) Any None test pms-link
2817 (l) 100–109
200–209
300–309
None
3073 (m) 70–79 None
3841 (n) 20–29 None