Maintenance-Object Repair Procedures
555-233-143
8-1296 Issue 1 May 2002
Notes:
a. An error took place in generating the error code.
b. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_EAL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10003
points to port network 4) List config port-network gives the cabinet
number associated with a port network.
c. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_INL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10003
points to port network 4) List config port-network gives the cabinet
number associated with a port network.
d. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_HW. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10203
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
e. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_PER. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10303
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
f. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the A-PNC associated with fault class FC_DS1. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (10403
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
18 None busy PNC-DUP WARNING ON release pnc-dup