Maintenance-Object Repair Procedures
555-233-143
8-1298 Issue 1 May 2002
m. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
PER. This indicates one or more faults on peer links that connect SNIs to
EIs. Investigate any alarms against SNI-PEER. Adding 1 to the last two
digits of the error code gives the PN number of the port network that
reported the alarm. (11303 points to port network 4.) List config
port-network gives the cabinet number associated with a port network.
n. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
DS1. This indicates faults on one or more DS1C facilities. Investigate any
alarms against DS1-FAC. Adding 1 to the last two digits of the error code
gives the PN number of the port network that reported the alarm. (11403
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
o. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
SNIL. This indicates one or more faults on peer or neighbor links between
SNIs on different switch nodes. Investigate any alarms against SNI-PEER.
The last two digits of the error code indicate the fiber-link number (01-64) of
the fiber that reported the retired alarm. List fiber-link gives the location of
the fiber.
p. A spontaneous PNC interchange took place in response to the occurrence
of a major or minor alarm on the A-PNC associated with fault class FC_
SNIHW. This indicates one or more faults on hardware connecting SNIs on
different switch nodes. Investigate any alarms against SN-CONF, SNI-BD,
FIBER-LK. The last two digits of the error code indicate the fiber-link
number (01-64) of the fiber that reported the retired alarm. List fiber-link
gives the location of the fiber.
q. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the B-PNC associated with fault class FC_EAL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (20003
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.
r. A spontaneous PNC interchange took place in response to the retiring of
an alarm on the B-PNC associated with fault class FC_INL. Use status
pnc to look at the state of health indexes for the PNCs, and investigate any
associated alarms. Adding 1 to the last two digits of the error code gives
the PN number of the port network that reported the retired alarm. (20103
points to port network 4.) List config port-network gives the cabinet
number associated with a port network.