Maintenance-Object Repair Procedures
555-233-143
8-1324 Issue 1 May 2002
PPP Link Status Inquiry Test (#1279)
This nondestructive test determines the state of the PPP link. The test passes
only if the link is up.
Table 8-533. Test #1279 PPP Link Status Inquiry Test
Error
Code
Tes t
Result Description / Recommendation
1124 ABORT ppp link is not enabled.
1. Verify that the ppp link is enabled (status port UUCSSpp, status link n, or
display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT PPP Link is not in service.
1. Verify whether PPP link is in-service (status port UUCSSpp or status link
n).
2. If the PPP link is not in service, release the link (release link n or release
port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
Continued on next page