Maintenance-Object Repair Procedures
555-233-143
8-1358 Issue 1 May 2002
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Analog Ring Generator Initialization test (#117), you may also clear errors
generated from other tests in the testing sequence.
Table 8-550. Analog Ring Generator Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any AnyAnytest environment UU
1 Analog Ring Generator Query
(#118)
MAJOR ON test environment UU r 3
Table 8-551. Multicarrier Cabinet
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Nondestructive
Analog Ring Generator Initialization test (#117) X X ND
Analog Ring Generator Query test (#118) X X ND
Battery and Battery Charger Query test (#5) (a) X X ND
AC Power Query test (#78) (b) X X ND
OLS Query test (Carrier E) (#127) (c) X X ND
OLS Query test (Carrier D) (#127) (c) X X ND
OLS Query test (Carrier A) (#127) (c) X X ND
OLS Query test (Carrier B) (#127) (c) X X ND
OLS Query test (Carrier C) (#127) (c) X X ND
Emergency Transfer Query test (#124) (d) X X ND
Cabinet Sensors Query test (#122) (e) X X ND
External Alarm Lead Query test (#120) (f) X X ND