S-SYN-PT (Speech Synthesis Port)
Issue 1 May 2002
8-1365555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. An in-line failure of the on-board microprocessor/PSS handshake has
occurred. Refer to Test #168 for repair procedures.
b. This error type indicates that the circuit pack been removed or has been
insane for more than 11 minutes. To clear the error, reinsert or replace the
circuit pack.
c. A transient error that does not cause an alarm can occasionally occur
during a server, TDM bus, or Tone-Clock interchange. Test the port, and
follow the instructions for the Conference test (#7).
d. This error is not service-affecting, and no action is required.
Table 8-555. Speech Synthesis Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 17672 None
18 0 busyout port UUCSSpp WARNING OFF release port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp sh
257 Speech Synthesis PSS
Handshake test (#168)
MAJOR ON test port UUCSSpp sh r 2
513 17922 Speech Synthesis
Memory test (#166)
MINOR ON test port UUCSSpp sh r 2
769 17664 Speech Synthesis DTMF
Receiver Inquiry test
(#164)
MINOR ON test port UUCSSpp sh r 2
1025 17670 Speech Synthesis SSD
Inquiry test (#167)
MINOR ON test port UUCSSpp sh r 2
1281 Speech Synthesis DSP
Tone test (#165)
MINOR ON test port UUCSSpp sh r 2
1537 Speech Synthesis
Memory test (#166)
MINOR ON test port UUCSSpp sh r 2
1793 Speech Synthesis DTMF
Receiver test (#163)
MINOR ON test port UUCSSpp l r 2
2049 (c) Conference Circuit test
(#7)
MINOR ON test port UUCSSpp l r 2
2305 NPE Crosstalk test (#6) MINOR ON test port UUCSSpp l r 2
3840 (d) Any None