S-SYN-PT (Speech Synthesis Port)
Issue 1 May 2002
8-1375555-233-143
Speech Synthesis Parameter Update Test (#169)
This test updates the dual-tone multifrequency (DTMF) interdigit time-out
parameter used by the Speech Synthesis circuit pack so that it is consistent with
that specified by the server.
Table 8-564. TEST #169 Speech Synthesis Parameter Update Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. Wait until the
port is idle (amber LED is off) before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL An internal system error has occurred.
PASS The DTMF interdigit time-out parameter has been updated.
1. User-reported troubles should be investigated using other tests and by
verifying that other ports on this circuit pack are working correctly.