SNC-BD (Switch Node Clock Circuit Pack)
Issue 1 May 2002
8-1421555-233-143
Clear Firmware Counters (#983)
This test number is used to report unsuccessful results of the clear
firmware-counters command. This is not an actual demand maintenance test. If
the command aborts, refer to the error codes listed for Test #777.
0NO
BOARD
No board was detected by the test.
1. Check that SNC board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNC should be reset
instead of reseating the circuit pack. The reset board command should
almost never be used on an SNC. It may be necessary to use the reset
board command if the SNC circuit pack gets into a mode where it cannot
communicate with software. If an SNC with active errors and alarms is
reset, the errors and alarms may take a while to come back, therefore the
reset board command can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
the board and retest.
Table 8-572. TEST #780 Switch Node Clock Reset Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page

Table of Contents