SNI-BD (SNI Circuit Pack)
Issue 1 May 2002
8-1439555-233-143
Error Log Entries and Test to Clear Values
Table 8-575. SNI Board Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each
appropriate test’s description, and follow its recommended procedures.
0 Any Any Any test board UUCSS r 1
1 (b) any failure audit (#777) (a) MAJOR
MINOR
WARNING
ON test board UUCSS r 1
18 (c) 0 busyout board UUCSS WARNING OFF release board UUCSS
125( d) None MINOR ON
257 (e) any failure audit (#777) (a) MAJOR
MINOR
WARNING
OFF test board UUCSS r 1
513 (f) any failure audit (#777) (a) MAJOR
MINOR
WARNING
OFF test board UUCSS r 1
769 (g) any failure audit (#777) (a) MAJOR
MINOR
WARNING
OFF test board UUCSS r 1
1025 (h) any failure audit (#777) (a) MAJOR
MINOR
WARNING
ON/
OFF
test board UUCSS r 1
1281 (i) any failure audit (#777) (a) MAJOR
MINOR
WARNING
ON test board UUCSS r 1
1537 (j) any failure audit (#777) (a) MAJOR
MINOR
WARNING
OFF test board UUCSS r 1
2561 (k) any failure audit (#777) (a) MAJOR
MINOR
WARNING
ON test board UUCSS r 1
2817 l) any failure audit (#777) (a) MAJOR
MINOR
WARNING
ON test board UUCSS r 1