Maintenance-Object Repair Procedures
555-233-143
8-1442 Issue 1 May 2002
3. Replace the fiber links other endpoint if no DS1C complex is
administered on the fiber link. (Use list fiber-link to
determine whether a DS1C complex is administered). If so,
replace the circuit packs in this order:
i. Replace the DS1C circuit pack connected to this SNI.
ii. Replace the other DS1C circuit pack.
iii. Replace the fiber links other endpoint.
i. This error indicates a processor complex failure.
1. Replace the SNI circuit pack.
j. This error indicates that excessive slips have occurred.
Follow the steps for diagnosing synchronization problems when
slips have occurred in the SYNC section.
k. This error indicates that the SNI cannot communicate with its neighbor.
The SNI is at fault.
1. Replace the SNI circuit pack.
l. This error indicates that the SNI cannot communicate with one of its peers.
The SNI is at fault.
1. Replace the SNI circuit pack.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Configuration audit (#759), you may also clear errors generated from other tests
in the testing sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence D/ND
1
1. D = Destructive, ND = Nondestructive
Configuration audit (#759) X X ND
Failure audit (#777) X X ND
Fiber Out of Frame query (#989) X X ND
Packet Neighbor test (#767) X X ND
Circuit Path test (#755) X X ND
Destructive Facility test (#757) X D
Off-board Destructive Facility test (#756) X D
Switch Node Interface Reset test (#761) X D