105 FAIL The SNI circuit pack cannot communicate with the SNI in slot 5 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 5. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 769. If other SNI circuit packs have SNI-PEER error
type 769, then replace the SNI in slot 5. Replacing an SNI may be service
interrupting. See ‘‘SNI-BD (SNI Circuit Pack)’’ on page 8-1429 for the
procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 769 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 5.
106 FAIL The SNI circuit pack cannot communicate with the SNI in slot 6 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 6. Use
display errors to find any SNI-BD errors and check display alarms to see
whether the errors have on-board alarms. Then follow the associated
repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 1025. If other SNI circuit packs have SNI-PEER
error type 1025, then replace the SNI in slot 6. Replacing an SNI may be
service interrupting. See the SNI-BD section for the procedure for
replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 1025 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 6.
Table 8-576. TEST #755 SNI Circuit Path Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page