SNI Off-Board Destructive Facility Test (#756)
This test is destructive.
The SNI runs a destructive loop around of the on-board and off-board
Looparound. This test returns the result of the off-board loop around, while
Test #757 returns the result of the on-board loop around.
Table 8-577. TEST #756 SNI Off-Board Destructive Facility Test
Error
Code
Tes t
Result Description / Recommendation
1015 ABORT The system will not allow this test to be run because the SNI circuit pack has
not been busied out. Busyout the SNI circuit pack with busyout board.
Repeat the test board UUCSS long command.
1415 ABORT The lightwave transceiver is absent.
1. If a lightwave transceiver should not be present, do nothing. For example,
an SNI connected to a DS1C circuit pack or an SNI with a metallic
connection does not have a lightwave transceiver. This test can only be
run when a lightwave transceiver exists.
2. Otherwise, check the lightwave transceiver connections.
3. If OK, replace the lightwave transceiver. If a fiber out of frame condition
exists and lightwave transceivers are used, check that the lightwave
transceivers are of the same type, that is, both are 9823a or both are
9823b. If they are not the same type, replace one of the lightwave
transceivers:
■ 9823a is used for distances up to 4900 feet.
■ 9823b is used for distances up to 25,000 feet.
4. If the test continues to abort, replace the SNI circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2304 ABORT SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.