Maintenance-Object Repair Procedures
555-233-143
8-1462 Issue 1 May 2002
103 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 3.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 257, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 257, replace the SNI in
slot 3. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
104 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 4.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 513, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 513, replace the SNI in
slot 4. Replacing an SNI may be service interrupting. See‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
105 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 5.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 769, replace the SNI
being tested. Replacing an SNI may be service interrupting. See ‘‘SNI-BD
(SNI Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 769, replace the SNI in
slot 5. Replacing an SNI may be service interrupting. See ‘‘SNI-BD (SNI
Circuit Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
Retry the command.
Table 8-579. TEST #759 Configuration Audit — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page