105 FAIL The SNI circuit pack cannot communicate with the SNI in slot 5 over the packet
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 5. Use
the display errors command to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board alarms.
Then, follow the associated repair procedures for the SNI-BD as described
in the Maintenance manual.
2. Using the display errors command, check the error log for other SNI
circuit packs with SNI-PEER error type 769. If other SNI circuit packs have
SNI-PEER error type 769 errors, replace the SNI in slot 5. Replacing an
SNI may be service interrupting. See ‘‘SNI-BD (SNI Circuit Pack)’’ on page
8-1429 for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 769 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
3. Replace the SNI being tested.
4. Replace the SNI in slot 5.
106 FAIL The SNI circuit pack cannot communicate with the SNI in slot 6 over the packet
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 6. Use
the display errors command to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board alarms.
Then, follow the associated repair procedures for the SNI-BD as described
in the Maintenance manual.
2. Using the display errors command, check the error log for other SNI
circuit packs with SNI-PEER error type 1025. If other SNI circuit packs
have SNI-PEER error type 1025 errors, replace the SNI in slot 6.
Replacing an SNI may be service interrupting. See‘‘SNI-BD (SNI Circuit
Pack)’’ on page 8-1429 for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 1025 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
3. Replace the SNI being tested.
4. Replace the SNI in slot 6.
Table 8-581. TEST #767 Packet Neighbor Link Test Continued