EasyManua.ls Logo

Avaya S8700 - Page 2205

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SNI-BD (SNI Circuit Pack)
Issue 1 May 2002
8-1483555-233-143
Failure Audit (#777)
This test is nondestructive.
This test queries an SNC for any existing failures and any unacknowledged
cleared failure messages. Each failure generates an error and alarm entry
against SNC-BD, SNC-LINK, or SNC-REF. A cleared failure message is a
message an SNI circuit pack sends to software indicating the resolution of a
previous failure. This message is unacknowledged if the SNI circuit pack never
receives a response from software indicating its own receipt of the original
cleared failure message.
If no failures are detected by the SNI circuit pack, this test will pass.
If this test reports failures, the results screen for the test board command will
show FAIL with no FAIL code. The error log must then be displayed via display
errors with category PNC to view every SNI-BD and FIBER-LK error and
category PNC-PEER to view every SNI-PEER error.
Table 8-582. TEST #777 Failure Audit
Error
Code
Test
Result Description / Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page