Maintenance-Object Repair Procedures
555-233-143
8-1500 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error type corresponds to FAIL code 1 of the Stratum-3 Clock Alarm
Query test (#649): either reference A failed or the CI card A failed.
b. This error indicates that Synchronization Maintenance has been disabled
via the disable synchronization-switch command. Execute the enable
synchronization-switch command to enable Synchronization
Maintenance reference switching and to resolve this alarm.
c. This error type corresponds to FAIL code 2 of the Stratum-3 Clock Alarm
Query test (#649): one power supply failed.
d. This error type corresponds to FAIL code 4 of the Stratum-3 Clock Alarm
Query test (#649): one clock unit failed.
e. This error type corresponds to FAIL code 8 of the Stratum-3 Clock Alarm
Query test (#649): either reference B failed or the CI card B failed.
Table 8-586. Stratum-3 Clock Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any Any Any test synchronization r 4
1(a) Any Stratum-3 Clock
Alarm Query (#649
MINOR OFF test synchronization r 4
18(b) 0 disable sync WARNING OFF enable sync
257(c) Any Stratum-3 Clock
Alarm Query (#649)
MINOR OFF test synchronization r 4
513(d) Any Stratum-3 Clock
Alarm Query (#649
MINOR ON test synchronization r 4
769(e) Any Stratum-3 Clock
Alarm Query (#649)
MINOR ON test synchronization r 4
1025(f) Any Stratum-3 Clock
Alarm Query (#649)
MINOR
MAJOR(h)
ON test synchronization r 4
1281(g) Any Stratum-3 Clock
Alarm Query (#649)
MINOR
/MAJOR(h)
ON test synchronization r 4
1537(i) none MINOR
MAJOR(h)
ON
1793(j) none MINOR
MAJOR(h)
ON