Maintenance-Object Repair Procedures
555-233-143
8-1538 Issue 1 May 2002
Test command for the system links, test sys-link UUCSSpp can be specified with
current or faulted as an optional argument if the user wishes to test every
component in the specified path. The tests executed will be the same if the user
were to test each component manually. In the event that the user does not
specify any path, then only the tests specified for the system links are executed.
System Link Status (#985)
This test is nondestructive. This test queries the switch for the status of the
system link and verifies that every switch component has the same view of the link
state.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1. D = Destructive, ND = Nondestructive
System Link Status (#985) X X ND
Table 8-596. TEST #985 System Link Status
Error
Code
Tes t
Result Description / Recommendation
1007 ABORT Could not locate the system link associated with this location
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
6 FAIL The system link is down.
1. Follow the procedure for Error Type 13.
PASS The system link is up.