ATMS Detail Report
This report is divided into two sections. The upper section lists the trunk group,
trunk type, trunk vendor, TTL type, and the user-defined threshold values
administered on page 4 of the Trunk Group form. The lower section lists the most
recent set of measurements for each member of the trunk group selected for the
report. Measurements that exceed the marginal threshold, but not the
unacceptable threshold, are highlighted. Measurements that exceed the
unacceptable threshold blink, identifying unusable trunks. When a marginal or
unacceptable measurement is found, scan the top section to find out how far the
measurement deviates from its defined threshold.
ATMS TRUNK MEASUREMENTS
Group: 78 Type: co Vendor: AT&T TTL Type: 105-w-rl
THRESHOLD VALUES
Loss dev at
1004Hz-loss 404Hz 2804Hz C-msg C-ntch SRL SRL
Min Max - + - + Noise Noise LO HI ERL
Marginal -2 21 9 9 9 9 55 74 0 0 0
Unacceptable -2 21 9 9 9 9 55 74 0 0 0
Trk Test Test Test -16dBm OdBm
Mem Date Time Rslt FE NE FE NE FE NE FE NE FE NE FE NE FE NE FE NE FE NE
1 10/04 14:25 pass 7 7 7 7 -2 -2 7 7 15 28 34 34 8 16 11 16 11 17
2 10/04 14:26 1920
3 10/04 14:27 1000
4 10/04 14:28 pass 7 7 7 7 -2 -2 7 7 15 29 38 34 8 16 11 15 11 16
5 10/04 14:29 pass 7 7 7 7 -2 -2 6 6 15 35 34 34 8 6 9 6 10 7
6 10/04 14:30 pass 7 7 7 7 -2 -2 6 6 15 26 34 34 8 16 9 13 10 16
7 10/04 14:31 pass 7 7 7 7 -2 -2 7 7 15 30 34 34 8 16 9 11 10 13
8 10/04 14:32 pass 6 6 6 6 -2 -2 6 6 15 25 34 34 10 17 11 16 12 17
9 10/04 14:33 pass 6 6 7 7 -1 -1 7 7 15 25 34 34 8 15 9 13 10 16
10 10/04 14:34 pass 6 6 7 6 -1 -1 7 7 15 36 34 35 8 6 9 6 10 7