EasyManua.ls Logo

Avaya S8700 - Page 2292

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-1570 Issue 1 May 2002
CRC Error Counter Test (#623)
This test is nondestructive.
This test reads the BRI ports CRC error counters that are maintained on the BRI
circuit pack. The Cyclic Redundancy Check (CRC) is a means of error detection
used to determine the integrity of data frame contents. The CRC error counter is
incremented by the circuit pack when it detects a CRC error. The test passes if
the value of the counter is 0 (that is, the error is cleared). If the counter is
non-zero, the test fails, and the value of the counter is displayed in the Error
Code field.
Receive FIFO Overflow Error
Counter Test (#625)
This test is nondestructive.
This test reads and clears the BRI ports Receive FIFO Overflow error counter
maintained on the TBRI-BD circuit pack. This counter is incremented by the
circuit pack when it detects an overflow of its receive buffers. The test passes if
the value of the counter is 0 (that is, the error is cleared). If the counter is
non-zero, the test fails, and the value of the counter is displayed in the Error Code
field. This error can occur either if:
Signaling frames are being received from the Packet bus at a rate sufficient
to overflow the receive buffers on the circuit pack for a port
A hardware fault is causing the receive buffers not to be emptied properly
by the circuit pack.
This test is useful for verifying the repair of the problem.
Table 8-610. Test #623 CRC Error Counter Test
Error
Code
Tes t
Result Description / Recommendation
ANY FAIL This error occurs when a frame with a bad CRC is received over the D channel
by the BRI board. This error is reported on a per-port basis when the counter
goes over the threshold. This error is most likely due to a problem with the
wiring or interference on the wiring caused by a noise source or no termination.
It usually does not indicate a problem with the circuit pack.
PASS The CRC error counter was read correctly and has a value of 0.
Continued on next page

Table of Contents

Other manuals for Avaya S8700

Related product manuals