Maintenance-Object Repair Procedures
555-233-143
8-1580 Issue 1 May 2002
Table 8-616. Test #256 Service State Audit Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT System resources required to run this test are not available. The port may be
on a valid call. Use status trunk to determine when trunk is available for
testing.
1. Check the results of Test #1251 (Signaling Link State Check).
1005 ABORT The test aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, a modem pool member or Music on Hold). This error
can be ignored.
1018 ABORT The test is disabled.
1. Enable maintenance by entering y in the
Maintenance Tests? field
on page 2 of the change trunk-group form.
1113 ABORT The signaling link has failed, so the system cannot send any messages on
behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State test).
1114 ABORT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
1116 ABORT The trunk is not in a service state which is appropriate for running the test. This
test is only performed in the OOS/FE state.
1117 ABORT A service state audit message is outstanding.
1. Wait two minutes and then try again.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS Wait 4 minutes and then check the Error Log for any new errors of type 3073. If
there are none, then both sides of the ISDN connection agree on the service
state; the negotiation succeeded. If there is a new 3073 error, then the
negotiation failed (the far-end switch twice failed to respond within 2 minutes).
The switch automatically retries every 15 minutes. If the trunk was initially
in-service, it is now placed in the maintenance/far-end state. Incoming calls
are accepted, but no outgoing calls can be originated. If an incoming call is
presented, another Service State Audit is immediately performed in an attempt
to put the TN2185 Trunk-Side ISDN-BRI channel in the proper state.
Continued on next page