TBRI-TRK (Trunk-Side ISDN BRI)
Issue 1 May 2002
8-1585555-233-143
2041 ABORT The call has timed out, perhaps because of a lack of system resources.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2066 ABORT Could not establish test call.
1. Retry the command at 1-minute intervals up to 5 times.
2067 ABORT The call has timed out, perhaps because of a lack of system resources.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2074 ABORT Bit and Block Error query failed.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, there may be a serious internal problem with
M/T-DIG (Maintenance/Test Digital Port). If this is the case, see ‘‘M/T-DIG
(Maintenance/Test Digital Port)’’ on page 8-1161.
2075 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2104 ABORT Call dropped or could not be originated.
1. Make sure service is provisioned by the network.
2. Check the administration of the far-end test line extension on the trunk
group administration form.
3. Check the administration of the test call BCC (Bearer Capability Class) on
the trunk group administration form.
4. Try the test again.
2201
2205
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
2206 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Table 8-618. Test #258 ISDN Test Call Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page