TONE-BD (Tone-Clock Circuit)
Issue 1 May 2002
8-1671555-233-143
Error Log Entries and Test to Clear Values
Table 8-648. Tone-Clock Circuit Pack Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test tone-clock PC sh
1 (a) 0 Circuit pack removed or
SAKI Sanity test (#53)
MINOR ON
18 (b) 0 busyout tone-clock PC WARNING OFF release tone-clock PC
23 (c) 0 None WARNING OFF
125 (d) None MINOR ON
126 (e) None MINOR ON
257 (f) 65535 Control Channel test
(#52)
MINOR ON test tone-clock PC r 20
257 (f) Any None
513 (g) Any None
769 (h) 4358 None
1025 (i) 4363 NPE Audit test (50) test tone-clock PC sh
1538 (j) Any None MINOR ON
2049 (k) 0 Clock Health Inquiry test
(#46)
MAJOR ON set tone-clock UC override
3
2305 (k) 0 Clock Health Inquiry test
(#46)
MAJOR ON set tone-clock UC override
3
2561 (l) Any None MAJOR ON
3329
(m)
0 None MINOR/
WARNING
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
3. For a TN2312 IPSI-supported port network, use the command set ipserver-interface.
OFF set tone-clock UC override
3
3840 (n) Any None
3848 (o) 0 Clock Health Inquiry test
(#46)
set tone-clock UC override
3
3856 (p) MAJOR ON set tone-clock UC override
3
3857,
3858 (q)
NONE MAJOR ON busyout/release
ipserver-interface
3872 (r) 0 None set tone-clock UC override
3
3999 (s) Any None