TONE-PT (Tone Generator)
Issue 1 May 2002
8-1687555-233-143
Table 8-653. Test #40 Tone Generator Transmission Test
Error
Code
Te s t
Result Description / Recommendation
None ABORT The system was not able to allocate all the resources needed for this test or
there was an Internal system error.
1 ABORT The system could not allocate all the resources needed to test the DTMF
tones.
1001 ABORT The system was not able to put the tone generation facility in the appropriate
mode to test it.
1002 ABORT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM bus via the test tdm port-network PN# command.
1. Retry the command at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a tone receiver for the test connection. This
can happen when the system is heavily loaded or there is not an IPSI or Tone
Detector circuit pack in the port network where this test is being executed.
1. Make sure there is an IPSI or Tone Detector circuit pack in the same port
network.
2. If the circuit pack is missing, install one in the same port network.
3. Allow approximately 1-minute for Tone Detector maintenance to run on
the newly inserted IPSI or Tone Detector circuit pack.
4. Retry the command at 1-minute intervals up to 5 times.
1022 ABORT Tone detection for the system is administered as wide broadband (tone
detection mode 5), and the Tone Detector used for this test was not a TN420C
(the only circuit pack with this capability). GPTD ports on other types of Tone
Detector circuit packs are taken out of service since they cannot provide the
administered function. Either:
■ Change the tone-detection mode administered on the system-parameters
country-options form. (Refer to Administrator’s Guide for Avaya
MultiVantage Software, 555-233-506.)
■ Remove all non-TN420C circuit packs from the system.
2000 ABORT Response to the test request was not received within the allowable time
period. System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1 (a) FAIL DTMF generation failed for the active tone generator.
105 (a) FAIL Generation of 440-Hz failed.
109 (a) FAIL Generation of 2225-Hz failed.
110 (b) FAIL Generation of 404-Hz level invalid.
Continued on next page