Maintenance-Object Repair Procedures
555-233-143
8-1710 Issue 1 May 2002
Figure 8-102. TN2242 Japan trunk TTC private network connections
To upgrade a system to the TN2242 circuit pack:
1. Busyout the UDS1-BD DS1-CONV circuit pack (busyout board UUCSS).
2. Remove the TN464 administration (change circuit pack, change ds1,
and change trunk group n).
3. Remove the UDS1-BD circuit packs.
4. Remove the JRC (Japan Radio Corporation) external converter and cable.
5. Insert the TN2242 circuit packs.
6. Connect the TN2242 to the TDM with the H600-513 cable assembly.
7. Administer the TN2242 circuit pack (see ‘‘Administration’’).
Figure Notes:
1. S8700 Multi-Connect system
2. TN2242 2-Mbit Japan trunk circuit
pack
3. H600-513 cable assembly cable. (See
‘‘H600-513 Cable Pinout’’).
4. TDM facilities
1 1
22
3 3
cydfjap2 LJK 012999
4 4

Table of Contents