UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1733555-233-143
NPE Connection Audit Test (#50)
The system sends the circuit packs on-board microprocessor a message to
update the network-connectivity translation for its SCOTCH-NPE chip.
Table 8-669. Test #50 NPE Connection Audit Test
Error
Code
Tes t
Result Description / Recommendation
None,
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1019 ABORT The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The circuit packs SCOTCH-NPE chip has been updated with its translation.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the boards translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.