Maintenance-Object Repair Procedures
555-233-143
8-1788 Issue 1 May 2002
Table 8-685. Test #1212 CPE Loop-Back Jack Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1. Retry the test ds1-loop UUCSS cpe-loopback-jack-test-begin
command at 1-minute intervals up to 5 times.
1005 ABORT CPE Loop-Back Jack test cannot be executed in the current configuration. To
run this test, the TN464F or later suffix UDS1 must be administered for
24-channel operation. The “Bit Rate” field on the DS1 circuit pack
administration form must be set to “1.544” for 24-channel operation.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039 ABORT The UDS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the IPSI or Tone-Clock
circuit pack via the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950 ABORT Another loopback/span test is already executing on the DS1 board or the board
is in a network-requested loop-back mode (line loopback or payload loopback).
The hardware error log will indicate whether a Customer Loop-Back Jack test,
Far CSU Loopback test, or the One-Way Span test is executing or if the board
is in line-loopback or payload-loop-back mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a loopback/span test
is already active, that test must be terminated using the test ds1-loop UUCSS
end-loopback/span-test command in order to execute this test.
Continued on next page