UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1799555-233-143
PASS The One-Way Span test has successfully began transmitting a framed 3-in-24
test pattern. The test will continue to run until the system technician enters the
test ds1-loop UUCSS end-loopback/span-test command or the release
board UUCSS command.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 8-687. Test #1214 One-Way Span Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page