Maintenance-Object Repair Procedures
555-233-143
8-1818 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1 (a) 0 Sanity MINOR ON
18 (b) 0 WARNING OFF release board UUCSS
217 (c) 0 None WARNING ON
257 65535 Control Channel
Loop test (#52)
MINOR ON test board UUCSS l r 20
257 (d)
513 (e) 4352–
4357
MINOR ON
769 (f) 4358
1281,
1290–1295 (g)
Any MINOR ON reset board UUCSS
1537,
1796 (h)
Any MINOR ON
1794 (i) MINOR ON
1798 (j)
2049 (k) Packet Interface
test (#598)
MINOR ON test board UUCSS l r 3
2305 2306 (l)
2561–2668 (m) Any
2817, 2819 (n) Congestion Query
test (#600)
MINOR ON test board UUCSS s r 3
3073 (o) Link Status test
(#601)
MINOR ON test board UUCSS s
3330 (p) MINOR ON reset board UUCSS
3586 (q)
3999 (q) Any None
3840 (r) 4096–
4102
3841,
3843 (s)
3842 (t) Receive FIFO
Overflow Error
Counter test (#596)
3844 (u) Any
Continued on next page