EasyManua.ls Logo

Avaya S8700 - Page 2562

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-1840 Issue 1 May 2002
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Loop-Around test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. See ‘‘SCOTCH Synchronous Loop-Around Test (#1275)’’ on page
8-1843 repair procedures.
b. Error Type 257: VAL port detected overrun or underrun condition that can
indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
2. See ‘‘SCOTCH Synchronous Loop-Around Test (#1275)’’ on page
8-1843 repair procedures to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
c. Error Type 3585: TDM Port Loop-Around test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. See the TDM Loop-Around Test (#1285) repair procedure.
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. There is no short test sequence for this MO. Every test is available in the long test sequence. Refer to each
appropriate tests description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp l
1 (a) 0 SCOTCH Sync
Loop-Around test
(#1275)
MINOR ON test port UUCSSpp l r 3
257 (b) 0 WARNING OFF
3585 (c) 0, 1 TDM Loop-Around
test (#1285)
MAJOR ON test port UUCSSpp l r 3
Continued on next page