Maintenance-Object Repair Procedures
555-233-143
8-1842 Issue 1 May 2002
Table 8-704. Test #1285 TDM Loop-Around Test
Error
Code
Tes t
Result Description / Recommendation
1000 ABORT The port is in use.
1. Retry the command when the port is idle. You can force the port to the idle
state with the busyout port UUCSS command.
2. Escalate if the problem persists.
This command is destructive, tearing down every call and link using the port.
1002 ABORT No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
1003 ABORT No more tone receivers idle for use in this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. Repeat the test.
3. If the problem persists, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
2100 ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
FAIL Received tones do not match transmitted tones.
1. Retry command at 1-minute intervals up to 3 times.
2. If the problem persists, see ‘‘TDM-BUS (TDM Bus)’’, ‘‘TONE-PT (Tone
Generator)’’, and Tone Receiver repair procedures.
3. If the problem persists, reset the board (busyout board UUCSS, reset
board UUCSS, and release board UUCSS). Repeat the test.
4. If the problem persists, replace the circuit pack.
PASS Port connections across the TDM bus function properly.
Continued on next page