Maintenance-Object Repair Procedures
555-233-143
8-1846 Issue 1 May 2002
Notes:
a. The circuit pack stopped functioning or it was removed from the system.
This alarm is logged approximately 11 minutes after the circuit pack is
removed and/or the SAKI Sanity test (#53) fails.
To resolve this error, insert a circuit pack in the same slot as the error
indicates, if the circuit pack is not already in the system. Or, if the circuit
pack is in the system and the red LED is on, then follow instructions for
Red alarms.
!
CAUTION:
If the TN788 Voice Conditioner circuit pack (VC-BD) is not Vintage 2
or later, it must be replaced.
b. This circuit pack is busied out by the busyout board UUCSS command.
c. Transient communication problems exist between the switch and this
circuit pack. Execute the test board UUCSS command and see the repair
procedures for the ‘‘Control Channel Loop-Around Test (#52)’’ on page
8-1848.
1025 (f) 4363 NPE Audit test (#50)
1281 (g) Any SAKI Sanity test (#53) MAJOR ON
1293 to
1294 (h)
46088
to
46096
SAKI Sanity test (#53) MINOR ON
1538 (i) 46082 MINOR ON
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
Table 8-706. VC-BD Error Log Entries Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page