VC-DSPPT
Issue 1 May 2002
8-1853555-233-143
Table 8-709. Test #1104 VC DSPPT Local TDM Loop-Back Test
Error
Code
Te s t
Result Description / Recommendation
1000
1001
ABORT System resources required to run this test are not available, or the port is busy
with a valid call.
1. Retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The traffic load on the
system is very high, or time slots may be out-of-service due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 5 times.
1003 ABORT The system could not allocate a Tone Detector for the test. The system is
oversized for the number of Tone Detectors present, or some Tone Detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004 ABORT The port is seized by a user for a valid call. Use the status station command
for the station associated with this port and determine whether the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test was not received from the VC-BD circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the port by using the
busyout port UUCSSpp and reset port UUCSSpp commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals up to 5 times.
03 FAIL The TDM Loop-Around test failed.
1. Replace circuit pack.
47 FAIL The Conference Circuit test failed.
1. Replace circuit pack.
PASS The VC DSP Port Local TDM Loop-Around test passed.