Maintenance-Object Repair Procedures
555-233-143
8-1876 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has been
physically removed from the system. This error type does not apply to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is
logged approximately 11 minutes after removal of the circuit pack or failure
of the SAKI Sanity test (#53).
Check for the physical presence of the circuit pack in the slot indicated by
the alarm. If the circuit pack is absent, insert one of the proper type. If the
circuit pack is present and its red LED is lit, see ‘‘LED Alarms without Alarm
Log Entry or with Error Type 1’’ on page 6-5.
b. This error indicates the circuit pack has been busied out. Release the
circuit pack via release board UUCSS.
Table 8-721. Common Port Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test board UUCSS sh r 1
1 (a) 0 Circuit pack removed or
SAKI Sanity test (#53)
MINOR ON
18 (b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
217 (f) 0 None WARNING ON
257 65535 Control Channel test
(#52)
MINOR ON test board UUCSS sh r
20
267 (f) 0 None WARNING ON
513 (h) Any None MINOR ON test board UUCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit test (#50) test board UUCSS l r 20
1281 (k) Ringing Application test
(#51)
MINOR ON test board UUCSS r 2
1538 (l) Any None WARNING
MINOR
ON
1793 (m) Neon test (#220) MINOR ON test board UUCSS r 2
3840 (n) Any None
3999 (o) Any None