Maintenance-Object Repair Procedures
555-233-143
8-1880 Issue 1 May 2002
NPE Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for every NPE (Network Processing Element) on
the circuit pack.
Table 8-722. Test #50 NPE Audit Test
Error
Code
Tes t
Result Description / Recommendation
None
2100
ABORT System resources required for this test are not available.
1019 ABORT Test already in progress.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The circuit pack’s NPEs have been updated with their translation.
EXTRA
BD
Certain circuit packs have limitations on how many circuit packs can be in the
system or port network such as the Maintenance/Test circuit pack (TN771B or
TN771C), the Tone Detector circuit pack (TN748B, TN748C or TN748D) and
the Call Classifier (TN744). The Maintenance/Test circuit pack allows only one
circuit pack per port network. The Tone Detector and Call Classifier allow only
10 circuit packs in each system. All additional circuit packs will return
EXTRA-BD and should be removed.
Any NO
BOARD
This is normal if the test is being done when: (a) the board is not physically in
the system or (b) the system is booting up. Otherwise, there is some
inconsistency between the physical configuration and the data kept in the
system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals up to 5 times.
Continued on next page