Maintenance Commands
555-233-143
7-8 Issue 1 May 2002
G700 Media Gateway Parameters
The parameters, GGGVSPP, may apply to select SAT command run against an
MO in the system; for example, test port 002V204
clear Used with test commands, this specifies that the test
sequence is to be repeated until any active alarms against
the maintenance object is cleared by the passing of tests or
until any test in the sequence fails.
If no such alarms are active, the sequence is run once.
The long clear combination clears every alarm against the
maintenance object if no errors are encountered. The
short clear combination clears only alarms pertinent to the
tests in the short sequence.
!
CAUTION:
If every tests passes, the long clear
combination clears every error counter. If
firmware counters are cleared while an actual
problem exists, customer service may degrade
due to calls being routed over faulty
components.
002V204 002 is the Media Gateway Number
V indicates that this system is a G700 Media Gateway
2 is the slot number from 1 to 4
04 is the port number from 1 to 22.
Table 7-2. Less-Common Test Command Parameters — Continued
Parameter Range Default Meaning