Common Output Fields
Issue 1 May 2002
7-11555-233-143
Test No. The number of the test run on the MO as part of a test command. Descriptions
of each test and its related error codes appear under the relevant MO. Other
commands such as clear firmware-counters and reset also report a test
number.
Result One of the following results:
■ PASS: The command successfully completed. For a test command this
indicates that no errors were detected by the test.
■ ABORT: The command was prevented from completing. See Error Code
below.
■ FAIL: Indicates that a serious error was detected by the test. See Error
Code below.
■ NO BOARD: The system does not detect a circuit pack in the location
specified on the command line.
■ CONFLICT: Another user was testing this maintenance object.
■ EPN-DOWN: The EPN holding the MO is inaccessible. The expansion
archangel link may be down.
■ DISABLED: The MO or test has been disabled by the tier 3 disable
command.
■ NOT ASSIGNED: The location specified does not have a circuit pack
administered to it.
■ EXTRA BOARD: This result can appear for the Maintenance/Test, Call
Classifier, Tone Detector, Announcemen, and Speech Synthesis circuit
packs. Each of these circuit packs has restrictions on how many can be in
the system or a port network:
— Maintenance/Test circuit pack: 1 per port network
— Tone Detector circuit pack: up to 50 per system
— Call Classifier circuit pack: up to 25 per system
— Speech Synthesis circuit pack: 40 per system
— Announcement circuit pack: 1 per system
Remove the extra circuit pack(s).
Error Code A number indicating the reason for a FAIL or ABORT result. For test
commands and other commands that return a test result, consult the tables of
test error codes under the relevant MO. For busyout, release, and reset
commands, see ‘‘Common Abort and Fail Codes’’.