Maintenance Commands
555-233-143
7-16 Issue 1 May 2002
EXTRA BD This result can appear for Maintenance/Test, Call Classifier, Tone
Detector, Announcement, and Speech Synthesis circuit packs. Each of
these circuit packs has restrictions on how many can be installed in the
system or in a port network. The restrictions are as follows:
TN771D Maintenance/Test: 1 / port network
TN748 Tone Detector: 50 / system
TN744 Call Classifier: 25 / system
Speech Synthesizer: 40 / system
TN750 Announcement: 1 / system
Remove any extra circuit packs.
1 FAIL For reset commands, the circuit pack was not successfully halted.
2 FAIL For reset commands, the circuit pack was not successfully restarted after
being halted. For both results, replace the circuit pack.
FAIL See the applicable maintenance object in Chapter 8,
‘‘Maintenance-Object Repair Procedures’’.
PASS The requested action successfully completed. If the command was a
reset, the circuit pack is now running and should be tested.
Table 7-3. Common Error Codes for Busyout, Release, Test, and
Reset Commands Continued
Error
Code
Command
Result Description/Recommendation
Continued on next page