change system-parameters maintenance
Issue 1 May 2002
7-81555-233-143
Output (Page 3)
The following example shows the output from page 3 of the change
system-parameters maintenance
command.
DS1 Maintenance
DSO
Loop-Around
Test Call
Extension
The extension used to set up a DSO loop-around connection for testing
non-ISDN DS1 trunks. The DSO Loop-Around Test Call feature is used
primarily for testing DSO channels associated with non-ISDN-PRI trunks.
The loop around is activated by dialing the test extension number; multiple
DSO loop-around connections can be established by placing multiple calls
to the loop-around extension.
For more information, see ‘‘Facility Test Calls’’ in Chapter 6, “Additional
Maintenance Procedures”.
Continued on next page
change system-parameters maintenance Page 3 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
MAINTENANCE SAVE TRANSLATION CORRUPTION AUDIT
Enable Translation Audit? y
Display Warning When Detected? n
Alarm When Detected? n
Block Save Translation When Detected? n